main_banner

news

YH-40B Concrete Curing Chamber Use And Operation

Use and operation

1. According to the instructions of the product, first place the curing chamber away from the heat source. Fill the small sensor water bottle in the chamber with clean water(pure water or distilled water), and put the cotton yarn on the probe into the water bottle.

There is a humidifier in the curing chamber on the left side of the chamber. Please fill the water tank with enough water((pure water or distilled water)),connect humidifier and chamber hole with pipe.

Plug the humidifier’s plug into the socket in the chamber. Open the humidifier switch to biggest.

2. Fill water into the bottom of the chamber with clean water((pure water or distilled water)). The water level must be more than 20mm above the heating ring to prevent dry burning.

3. After checking whether the wiring is reliable and the power supply voltage is normal, turn on the power. Enter the working state, and begin to measure, display and control the temperature and humidity. Don’t need to set any valves, all values(20℃,95%RH) are setted well in factory.

Note: When humidity is more than 95% in the chamber, the humidifier stops work.While humidity is less than 95%,the humidifier can automaticly work again.

Also temperature is automatic controlled.

The following picture is the humidifierInstallation method.

humidifier


Post time: May-25-2023