main_banner

news

Customer Order laboratory biochemical cooling incubator

1、 Summary This machine was used in department of environment protect、sanitary and antiepidemic、drug supervision、marine lives. It is the special equipment for Liquid test and culture、save the BOD test、Bacillus、Mold、Microorganism. Constructure Characteristic A .The case is adoptes high quality cold-rolled steel plate with the plastic spraying on the surface. B .Mirro-stainless working room, easy clean, Shelves can be adjusted. C .Micro-Computer Tem. Controller and Automatic defrosting system, can make sure the high precise and working continue, big LCD Screen. D. Sole Tem.limited alarm system、Over-Tem. cut off electric and timing function, can make sure the safety operate. E .R134A famous compressor and fans. F. Double doors, inner door is the good quality steel-glass, silicon seal, outside door is the magnetic silicon, easy open and close, make sure the good seal. G. ¢50mm big test hole, can test the chamber line、power and other condition. H. Optional function ①RS-485/232 connector, can contact with the computer ②Typer(minisize) ③Alarm system when electric cut off. ④Cut off electric or Alarm function when open the door ⑤Creepage protect The above Optional parts should be made by our company.2、Diagram Specification、Specification Diagram

Working Condition

① Environment Tem.: 5~32℃(if setting tem.≦10℃,environment ≦28℃). ② Humidity:≦80%RH ③ Air Pressor: 80-106Kpa ④ There was no shake of the incubator and not caustic air around the chamber. ⑤ Should avoid light and cooling environment. ⑥ Keep distance of the dust, isntall horizontal and make sure a distance between the equipment and wall. ⑦ Good airiness.

Safety Items 1 After you received the equipment, to avoid the damage for the compressor during a long transport, please keep the machine leave 1 days and then can use. To make sure equpment and test safety, please install the outer protect and also use the power as the equpment required.

2 Do not test the flammable and conmustible、poisonous and corrosive material.

3 The equipment should be installed horizontal.

4 Only the engineer can disassmebly and repair.

5 If put one working equipment into the chamber, once the power bigger than 2A, please add the power outside, please do not use this equipment power.

6 When the chamber tem.≧50℃, please do not setting the low tem. to avoid the compressor working, to make sure the compressor can be used long time.

7 Once alarm operate, please resolve this problem, please do not turn on the machine.

8 Please read this manual operation and then operat this machine.

微信图片_20191217145029

laboratory drying oven muffle furnace

Laboratory instruments cement concrete

Contact informations


Post time: May-25-2023