main_banner

Product

200 Ton 2000KN Automatic Test Equipment Steel Rebar Universal Tensile Testing Machine

Short Description:


Product Detail

Product Tags

  • Product Description

WE Series Universal Testing Machine

1.Matters need attention

Please read this manual carefully before using this equipment, and keep it forfuture reference purposes

The installation environment requirements:

① Environment temperature 10 ℃ ~35 ℃

② Relative humidity of not more than 80%

③ No vibration, no corrosion, no strong electromagnetic interference environment

④ The levelness should be no more than 0.2mm/1000mm

⑤ There should be around 0.7m space, equipment must be reliably grounding.

Power requirements:

This equipment use 380v three-phase four-wire (in addition to the other tips)alternating current (AC), voltage stability, do not exceed ±10% of the rated voltage,theallowable current of the sockets shall not exceed 10A.

Hydraulic oil requirements

The equipment adopts standard hydraulic oil as the working fluid:when the room temperature is higher than 25 ℃ ,using No.68 anti-wear hydraulic oil . when the room temperature is below 25 ℃ ,using No.46 anti-wear hydraulic oil. In winter, when the room temperature is too low, after turning on the machine please

preheating equipment (start the oil pump motor) for 10 minutes. When frequent using,

hydraulic oil should be replaced half a year, whether the fuel tank and filter should be

cleaning or not is decided by the pollution degree .

This equipment can not use engine oil, gasoline or other oil for instead. Failure ofthe hydraulic component due to the improper Oil , will not be included in the scope of warranty.

About the emergency stop

In case of an emergency in the installation, operation, such as solenoid valves cannot release, abnormal operation of motor, which may causes damage to the machine or injury of tester, please turn off the circuit breaker.

Precision

Equipment is exactly calibrated before leaving the factory, do not adjust thecalibration parameters. Measurement error increases due to unauthorized adjustment for the calibration parameters, will not be included in the scope of warranty. You can contact with local quality supervision department for calibration according to the

equipment marking accuracy class.

Maximum force

Determine the measuring range of equipment according to the equipment label,measuring range is adjusted in factory, do not alter the range parameter, adjustment of the range parameters could result in equipment output force is so large that causes damage to the mechanical parts or output force is so small that can not reach the

setting value, the damage of mechanical components due to unauthorized adjustmentfor range parameters , will not be included in the scope of warranty.

2.General introduction

WE series universal material testing machine

This series testing machine is mainly used for tensile testing, compress testing,bend testing, shear testing of metal, non metal materials,intelligent LCD display loading curve, force value, loading speed, displacement and so on ,recording data automatically, test results can be printed.

WE DATA

Test photoWE300B

Contact informations


  • Previous:
  • Next: